CIVIL
STRUCTURE
-R.C.C framed structure, designed as per relevant BIS codes for earth quake resistance and structurally efficient systems implemented.
WALLS
- External walls with 6" solid concrete blocks and internal walls with 4" solid concrete blocks.
PLASTERING
- Sponge finish for external walls & Smooth sponge finish for internal walls.
ARCHITECTURE DOORS
- Main Door - Engineered wooden door. full width jamb (with architrave)
- Main Door fitted with digital door lock
-Internal doors - Engineered wooden doors with laminate
WINDOWS
- UPVC sliding windows with mosquito mesh and MS safety
FLOORING
- Living, kitchen and dining.
- bedrooms: double charged vitrified tiles.
BATHROOM
- Floor: Antiskid ceramic tiles flooring
-Walls: Glazed ceramic tiles
-False ceiling: Grid false ceiling with PVC coated tiles and shadow channels.
PAINT
- External walls: Exterior grade emulsion
- Internal Walls: Emulsion over wall care putty
PLUMBING, ELECTRICAL & SERVICES
CP & SANITARY FITTINGS & FIXTURES
- Grohe or jaguar or equivalent make ISI CP and sanitary fittings.
- TOTO or equivalent soft close seat cover EWC
- TOTO or equivalent monolithic one piece sink
ELECTRICAL
-Wipro switches or equivalent
-Fire resistant anchoror polycab or equivalent.
ELECTRICAL POINTS
- Provision of electrical points for refrigerator, chimney and washing machine.
- TV & Telephone point in living room.
- Electrical point for geyser & exhaust in toilets.
- AC point for master bedrooms
GRID POWER AND BACKUP POWER
- EB power: 3 KW
-DG power backup: 1 KW
- Common areas: 100% backup for lighting, lifts and utilities.
ELEVATOR
- 6/8 Passenger capacity elevator of repute make.